  1. Power Supply > PS/2 Type Power Supply > ACE-A130C
  2. 64-ch Digital I/O and Counter ISA Card
    • 32 TTL-level digital input channels
    • 32 TTL-level digital output channels
    • High-output driving capacity
    • Low-input loading
    • 3 programmable counter/timer channels
    • User configurable clock source
    • Breadboard area for custom circuits
    Learn More
  3. Power Supply > PS/2 Type Power Supply > ACE-935AL
  4. 7RTD IoT Modbus/SNMP/MQTT Ethernet Remote I/O
    • 8ch RTD
    • Protocols:Modbus TCP,ASCII
    • GCL to perform basic logic control rules
    • Peer-to-Peer function to map I/O status
    • Wiring burn-out detect function
    • Isolation protection: 2000VDC
    Learn More
  5. 25 kS/s, 12-bit, 32-ch Isolated Analog Input ISA Card
    • 32 single-ended analog input channels
    • 12-bit A/D converter, with up to 100 kHz sampling rate
    • Isolation protection (500 VDC)
    • Program-controlled A/D trigger and data transfer
    Learn More
  6. Power Supply > PS/2 Type Power Supply > ACE-4840APM
    ● Internal 8 cm fan ● Meets medical safety standards ● Line input fuse protection ●Output overvoltage protection ● Short circuit protection on all outputs ● Total +12 V output up to 34 A Learn More
  7. 6-ch, 16-bit Counter/Timer ISA Card
    • Periodic interrupt generation
    • 6 independent 16-bit counters
    • Digital filter for noise reduction
    • Binary or BCD counting
    • Programmable frequency output
    • Complex duty-cycle output
    • Single-shot output
    • 16-bit TTL input and 16-bit TTL output ports
    • Selectable interrupt input channel
    • Up to 10 MHz input frequency
    • Pulsewidth and period measurement
    • Time-delay generation
    • F/V conversion and accumulation
    Learn More
  8. 8DI/7DO PROFINET Fieldbus Remote I/O
    • 8ch digital input/7ch digital output
    • Protocol : PROFINET
    • 2 x RJ-45 LAN for Daisy-chain connectivity
    • 2500VDC isolation protection
    Learn More
  9. 6Relay PROFINET Fieldbus Remote I/O
    • 6ch relay
    • Protocol : PROFINET
    • 2 x RJ-45 LAN for Daisy-chain connectivity
    • 2500VDC isolation protection
    Learn More
  10. Embedded Computer > Single Board
    ● 3.5” form factor with AMD Geode™ LX 800 CPU ● One 333/400 MHz DDR SO-DIMM socket supports up to 1 GB memory ● VGA, 24-bit TTL, 18-bit LVDS display interfaces ● Seven RS-232 and one RS-232/422/485 ● IEI One Key Recovery solution allows you to create rapid OS backup and recovery Learn More