  1. Modbus Gateways
    • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
    • Integration of Modbus TCP and Modbus RTU/ASCII networks
    • Supports up to 921.6 kbps, and any baud rate setting
    • support up to 16 connections on each serial port under Modbus Master mode and 32 sessions under Modbus Slave mode.
    • Software selectable RS-232/422/485 communication
    • Mounts on DIN-rail and Wall mount
    • Built-in 15 KV ESD protection for all serial signals
    • Automatic RS-485 data flow control
    • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV
    • Support a wide operating temperature
    Learn More
  2. Accelerometer Magnetic Mounting Base
    • Magnetic mounting base for Model BB-HS-104T2505402 sensor
    • Pole-piece magnet
    • Mounts on curved surfaces
    • Up to 120 °C (248 °F) operating temperature
    • Optional, sold separately
    Learn More
  3.  Modbus Gateways
    • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
    • Integration of Modbus TCP and Modbus RTU/ASCII networks
    • Supports up to 921.6 kbps, and any baud rate setting
    • support up to 16 connections on each serial port under Modbus Master modeand 32 sessions under Modbus Slave mode.
    • Software selectable RS-422/485 communication
    • Mounts on DIN-rail and Wall mount
    • Built-in 15 KV ESD protection for all serial signals
    • Automatic RS-485 data flow control
    • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV
    • Support isolation and wide operating temperature
    Learn More
  4.  Modbus Gateways
    • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV.
    • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
    • Integration of Modbus TCP and Modbus RTU/ASCII networks
    • Supports up to 921.6 kbps, and any baud rate setting
    • support up to 16 connections on each serial port under Modbus Master mode and 32 sessions under Modbus Slave mode.
    • Software selectable RS-232/422/485 communication
    • Mounts on DIN-rail and Wall mount
    • Built-in 15 KV ESD protection for all serial signals
    • Automatic RS-485 data flow control
    Learn More
  5.  Modbus Gateways
    • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
    • Integration of Modbus TCP and Modbus RTU/ASCII networks
    • Supports up to 921.6 kbps, and any baud rate setting
    • support up to 16 connections on each serial port under Modbus Master mode and 32 sessions under Modbus Slave mode.
    • Software selectable RS-422/485 communication
    • Mounts on DIN-rail and Wall mount
    • Built-in 15 KV ESD protection for all serial signals
    • Automatic RS-485 data flow control
    • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV
    • Support isolation and wide operating temperature
    Learn More
  6.  Modbus Gateways
    • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
    • Integration of Modbus TCP and Modbus RTU/ASCII networks
    • Supports up to 921.6 kbps, and any baud rate setting
    • support up to 16 connections on each serial port under Modbus Master mode and 32 sessions under Modbus Slave mode.
    • Software selectable RS-232/422/485 communication
    • Mounts on DIN-rail and Wall mount
    • Built-in 15 KV ESD protection for all serial signals
    • Automatic RS-485 data flow control
    • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV
    • Wide operating temperature
    Learn More
  7.  Modbus Gateways
    • Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
    • Integration of Modbus TCP and Modbus RTU/ASCII networks
    • Supports up to 921.6 kbps, and any baud rate setting
    • support up to 16 connections on each serial port under Modbus Master mode and 32 sessions under Modbus Slave mode.
    • Software selectable RS-232/422/485 communication
    • Mounts on DIN-rail and Wall mount
    • Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV.
    • Built-in 15 KV ESD protection for all serial signals
    • Automatic RS-485 data flow control
    Learn More
  8.  Modbus Gateways
    • 1 x 10/100 Mbps Ethernet ports and 1 x 100 Mbps Fiber port
    • Integrates Modbus TCP and Modbus RTU/ASCII networks
    • Supports up to 921.6 kbps and any baud rate setting
    • Supports up to 16 connections per serial port under Modbus master mode and 32 sessions under Modbus slave mode
    • Software-selectable RS-232/422/485/485-4w communication
    • Mountable via DIN rail and wall mount
    • Built-in 15 kV ESD protection for all serial signals
    • Automatic RS-485 data flow control
    Learn More
  9. Modbus Gateways
    • Supports Modbus/ASCII, RTU Protocol to control devices
    • Allows up to 8 clients to access field data simultaneously
    • Up to 31 Independent serial ports if configured to RS-485 serial mode
    • Surge protection for RS-485 and power line
    • Provides auto-searching device ID Windows utility
    • Automatic RS-485 data flow control
    • Easy mounting on DIN-rail or panel
    • Supports popular HMI software with Modbus/TCP driver or OPC server
    • Supports 10/100 Mbps communication speeds
    Learn More
  10. 4-ch Thermocouple Input Module
    • Resolution: 16-bit
    • Temperature Range: Type J ( 0 ~ 760°C) Type K ( 0 ~ 1370°C) Type T (-100 ~ 400°C) Type E (0 ~ 1000°C) Type R (500 ~ 1750°C) Type S (500 ~ 1750°C) Type B (500 ~ 1800°C)
    • Isolation Voltage: 2000 VDC
    • Input TypeL: J, K, T, E, R, S, B Type Thermocouple
    • Burn-out detection: Yes
    • Channels: 4