Industrial Automation

Industrial Automation

Grid List

Set Descending Direction

681-690 of 1049

  1. 8-ch Ultra High Speed Analog Input Module
    • Accuracy: ±0.1% or better
    • Effective resolution: 12-bit
    • Input range: ±10 V, +0 ~ +10 V, +0 ~ +20 mA, +4 ~ +20 mA
    • Isolation voltage: 3000 VDC
    • Sampling rate: 50K sample per sec (8 Channels)
    • Fault and overvoltage protection: withstands overvoltage up to ±35 V
    • lnput type: mV, V, mA
    • Channels: 8 differential
    Learn More
  2. 7-ch Thermocouple Input Module with Independent Input Range
    • Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 Hz
    • Sampling Rate: 10 samples/sec. (total)
    • High Common Mode: 2000 VDC
    • Isolation Voltage: 3,000 VDC
    • Fault and Overvoltage Protection: Withstands over voltage up to ±35 V
    • CMR @ 50/60 Hz: 92 dB min
    • Input Impedance: 20 MΩ. (Build-in 120 Ω Register for Current Input)
    • Built-in TVS/ESD Protection
    Learn More
  3.  Network Modules
    • 4 of IEEE802.3 af/at compliant PoE ports
    • Advantech PoE Control Utility for port management
    • Supported on FWA system
    Learn More
  4. 4-ch Analog Output Module
    • Accuracy: ±0.1% of FSR for current output
    • Effective resolution: 12-bit
    • Isolation voltage: 3000 VDC
    • Output range: 0 ~ 20 mA, 4 ~ 20 mA, 0 ~10 V
    • Resolution: ±0.015% of FSR
    • Channels: 4
    • Output type: mA, V
    Learn More
  5. Network Modules
    • 2x Intel i350-AM4
    • 8 Ports SFP
    • 1x PCIe x4, Gen2
    Learn More
  6.  Network Modules
    • 2x Intel i350-AM4
    • 4 Ports 1GbE Copper + 4 Ports 1GbE SFP
    • 1x PCIe x4, Gen2
    • 2 pairs Advanced LAN Bypass (optional)
    • RoHS Compliant
    Learn More
  7. Network Modules
    • 2x Intel i350-AM4
    • 8 Ports RJ45 connector
    • 1x PCIe x4, Gen2
    • 4 pairs Advanced LAN Bypass (optional)
    • RoHS Compliant
    Learn More
  8. Network Modules
    • 2x Intel® i350_AM4
    • 8 ports RJ45 connector
    • 2x PCI-E 2.0 x4
    • Lan Bypass model available
    • RoHS compliant
    Learn More
  9. 16-ch Universal Digital I/O Module
    • Digital input: Support Dry/Wet Contact
    • Digital output: Open Collector to 30 V, 450 mW max. load
    • I/O Type: bit-wise selectable by DIP switch
    • Power consumption: 0.35 W (typical); 1.2 W (max)
    • Channels: 16
    Learn More
  10.  Network Modules
    • 2 x Intel i350-AM4
    • 4 Ports 1GbE Copper + 4 Ports SFP
    • PCI-E 2.0 x4
    • RoHS compliant
    Learn More