  1. Lightning Arrestor - 0 to 1 GHz, 5000 A Protection, Bulkhead Pass-through
    Coaxial surge protector 4 GHz Low insertion losses Waterproof Removable GDT DC-pass Bi-directional protection Learn More
  2. Lightning Arrestor - 0 to 4 GHz, 20kA/10kA Protection, Bulkhead Pass-through
    Impedance: 50 Ohms (nominal) + Connector 1: Plated brass N female + Connector 2: Plated brass N female (bulkhead) + Gas discharge tube Learn More
  3. Serial Isolator, CAN, TB
    • Boost signals and increase node capacity of CAN networks
    • Works with various CAN protocols and frame lengths
    • 2,000V optical isolation protection from surges and spikes
    • Data rate: up to 250 kbps (bit-wise enable)
    • Terminal block CAN connections (copper)
    • DIN rail mount enclosure - ideal for industrial cabinets
    • 10-30 VDC external power required (not included, sold separately)
    Learn More
  4. Serial Surge Protector, RS-422/485 Data Line, Fused
    Protects RS-422 or RS-485 ports 600W serial circuit surge suppression 125 mA fast-acting PCB fuses Simple in-line installation One time use, disposable unit Learn More
  5. Serial Surge Protector, RS-232 Data Line, 3 Stage
    Three stages of protection on every data line: 1)Gas discharge tube, 2)Series resistor, 3)Transient voltage suppressor Protected signal ground connection Five Postion Terminal Block Dedicated chassis ground lug Learn More
  6. Serial Surge Protector, RS-422 Data Line, 3 Stage
    Three stages of protection on every data line: 1)Gas discharge tube, 2)Series resistor, 3)Transient voltage suppressor Protected signal ground connection Five Postion Terminal Block Dedicated chassis ground lug Learn More
  7. Serial Surge Protector, RS-485 Data Line, 3 Stage, DIN
    Three stages of protection on every data line: Gas discharge tube, Series resistor, Transient voltage suppressor Protected signal ground connection Terminal Block Dedicated chassis ground lug DIN Rail Mounting Learn More
  8. Isolated RS-422/485 Repeater
    Automatic RS-485 data fl ow control 3000 VDC isolation protection Surge protection RS-485 data line Transmission speed up to 115.2 Kbps LED indicator to monitor status Learn More
  9. Isolated Wide Operation Temperature RS-422/485 Repeater
    Wide Operating Temperature: -40 ~ 85° C Automatic RS-485 data flow control 3000 VDC isolation protection Surge protection RS-485 data line LED indicator to monitor status Learn More
  10. Serial Surge Protector, RS-485 Data Line, 3 Stage
    Three stages of protection on every data line: 1)Gas discharge tube, 2)Series resistor, 3)Transient voltage suppressor Protected signal ground connection Three Postion Terminal Block Dedicated chassis ground lug Learn More